— = Not applicable.
13 SEER HP WITH AV / SV / F*FV - VARIABLE SPEED
THGD18S41S1
AV24 17  –
550 
17.0 
13.0 
14.00 
12.00 
THGD24S41S1
AV24 17  –
750 
23.0 
17.2 
14.00 
12.00 
AV36 21  –
750 
23.0 
18.0 
14.00 
12.00 
THGD30S41S1
AV36 21  –
1000 
29.0 
24.4 
14.00 
12.00 
THGD36S41S1
AV36 21  –
1250 
35.0 
28.0 
13.50 
11.50 
THGD42S41S1
AV/SV48 24 
1400 
41.5 
32.0 
14.00 
12.00 
THGD48S41S1
AV/SV48 24 
1600 
47.5 
36.2 
14.00 
11.80 
AV/SV60 24 
1650 
47.5 
36.6 
14.00 
11.80 
F4FV060 24 
1600 
47.5 
36.2 
14.00 
11.80 
13 SEER HP WITH AHP / SHP / F*FP
THGD18S41S1
AHP18 17 
600 
17.0 
12.7 
13.00 
11.00 
F4FP024 17 
600 
17.0 
12.6 
13.00 
11.00 
THGD24S41S1
AHP30 17 
800 
23.0 
17.2 
13.00 
11.00 
F4FP030 17 
800 
23.0 
16.9 
13.00 
11.00 
THGD30S41S1
AHP36 21 
1000 
29.0 
23.2 
13.00 
11.00 
F4FP040 21 
1000 
29.0 
22.6 
13.00 
11.00 
THGD36S41S1
AHP36 21 
1200 
35.0 
26.8 
13.00 
11.00 
F4FP045 24 
1200 
35.0 
26.8 
13.00 
11.00 
THGD42S41S1
AHP/SHP48
21
1400
41.5
31.4
13.00
11.00
F4FP045 24 
1400 
41.0 
31.2 
13.00 
11.00 
F5FP048 24 
1450 
41.0 
32.6 
13.00 
11.00 
THGD48S41S1
AHP/SHP60 24 
1600 47.0 36.0 14.00 
11.50 
F5FP048 24 
1700 
47.5 
36.6 
14.00 
11.50 
F5FP060 24 
1700 
47.5 
36.8 
14.00 
11.50 
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. 
Cooling MBH based on 8
0°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power 
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL
W
RATED
CFM
NET MBH
SEER
EER
TOTAL
SENS.