Toshiba RAS-B10GKVP-E User Manual

Page of 116
– 21 –
7-2. Operation Data
<Cooling>
<Heating>
Temperature
condition (°C)
Indoor
Outdoor
27/19
35/–
Model name
RAS-
B10GKVP-E
B13GKVP-E
B16GKVP-E
Standard
pressure
P (MPa)
0.9 to 1.1
0.8 to 1.0
0.7 to 0.9
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
13 to 15
42 to 44
11 to 14
42 to 45
  8 to 11
43 to 47
Indoor
fan mode
High
High
High
Outdoor
fan mode
High
High
High
Compressor
revolution
(rps)
37
59
82
Temperature
condition (°C)
Indoor
Outdoor
20/–
7/6
Model name
RAS-
B10GKVP-E
B13GKVP-E
B16GKVP-E
Standard
pressure
P (MPa)
2.2 to 2.4
2.5 to 2.7
2.8 to 3.0
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
37 to 39
0 to 3
42 to 45
0 to 2
48 to 49
0 to 2
Indoor
fan mode
High
High
High
Outdoor
fan mode
High
High
High
Compressor
revolution
(rps)
54
65
86
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
2. Connecting piping condition : 7.5 m