Keep the air hose as short and free of cur-
ves as possible to avoid bottlenecks.
Air-conditioning with installation
If required, your appliance can be installed semi-
permanently (Fig. 6).
Proceed as follows:
•  Drill  a  5.27  inch  (134  mm)  dia.  hole  in  an
outside wall or through a window pane, re-
specting the heights shown in fig. 7.
•  Fit the flange accessory (S) provided in the
hole following the indications in figs. 8, 9 and
10.
12 inch
30 cm
30 cm
12 inch
MAX 39 inch
MIN 14 inch
in the window pane
in the wooden kickboard of a French window
in the wall: you are recommended to insulate
the section of wall using suitable insulation.
•  Fit the air exhaust hose (K) in the housing at
the back of the appliance (fig. 1).
•  Fit the end of the hose to the flange (S).
When the hose is not fitted, the hole can be
closed with the flange cap.
•  Remove the cap at the back of the appliance
(G) and replace with the drain hose plus cap
(U) as shown in figure 11. This enables the
condensate to be drained more easily at the 
end of the season. See the section: “END OF
SEASON OPERATIONS”.
Keep the air hose as short and free of cur-
ves as possible to avoid bottlenecks.
When installing the air conditioner semi-
permanently, you should leave a door slightly 
open, as little as 0.5 inch (1 cm), to guarantee 
correct ventilation.
 
  6
 
8
 
9
  10
 
7
134
5 inch