Millennium Enterprises Z33 User Manual

Page of 92
882108-YIM-B-1012
Johnson Controls Unitary Products
5
NOMENCLATURE
12
3
4
CONTROL
ADDITIONAL
D = SYNTHESYS CONTROL
CONFIGURATION
VOLTAGE
E = SYNTHESYS CONTROL, 
OPTIONS
2 = 208/230-60
       DISC., 110V OUTLET
Cu/Cu Condenser Coil
3 = 380-60
F = SYNTHESYS, DISC.
Cu/Cu Evaporator Coil
4 = 460-60
Exhaust VFD (Custom
er)
5 = 575-60
H = SIMPLICITY CONTROL  
 (see note 3)
7 = 380/415-50
I = SIMPLICITY CONTROL, DISC
    NOTES:
     110V OUTLET
1.  
108KW not available with 208/230V.
J = SIMPLICITY CONTROL,
* Premium Cabinet (6 doors)
2.  
Standard efficiency
 m
o
tor m
e
ets Canadian
     DISC, NO 110V OUTLET
* Standard Cabinet (4 doors)
ID BLOW
ER 
(S
ee note 4)
m
inim
u
m
 efficiency
 regulations m
a
ndated 
K = SIMPLICITY CONTROL W
/SIMPLICITY  LINC
* Drain Pan - powder coat
in Canadian Energy
 Efficiency
 Regulations.
L = SIMPLICITY CONTROL W
/SIMPLICITY  LINC
* Drain Pan - stainless steel
3.  
(VFD-CUSTOMER) = Wired for VFD
    DISC, 110V OUTLET
only
; VFD will be custom
er supplied and
M = SIMPLICITY CONTROL W
/SIMPLICITY  LINC
N = YCCS CONTROL
P = YCCS CONTROL W/DISC., 110V OUTLET
Q = YCCS ZONING CONTROL
R = YCCS ZONING CONTROL W/DISC.,
       110V OUTLET
S = YCCS-VAV CONTROL
T = YCCS-VAV CONTROL W/DISC.,
       110V OUTLET
field installed. If VFD Exh is also
     DISC, NO 110V OUTLET
specified, it will also be cust supplied.
4.  
VAV ID Blower requires hot gas by
pass .
5.  
Power exhaust and barom
etric relief not
available in end return configuration.
CONFIGURATION
6.  
Air foil fan available on cooling only
.
A = 1,2
  1 - BOTTOM RETURN
Contact engineering for 
B = 1,4
  2 - BOTTOM SUPPLY
air foil applications.
C = 1,5
  3 - END RETURN 
(5)
Air Volum
e
ECONOMIZER
D = 3,2
  4 - REAR SUPPLY
a = CV
A = DUAL ENTH Low leak type
E = 3,4
  5 - FRONT SUPPLY
b = VAV (VFD-FACTORY INSTALLED)
B, = SINGLE ENTH Low leak type
F = 3,5
c = BYPASS FACTORY VFD
C, = DRY BULB ENTH Low leak type
FRONT SUPPLY - COOLING ONLY
d = VAV (VFD-CUSTOMER)
 (3)
D = MANUAL  Low leak (Not w/PE)
HOT WATER, STEAM & ELECTRIC HEAT -
 
Fan (See note 6)
E = NONE
BOTTOM SUPPLY ONLY 
e = FORW
ARD CURVE FAN Class I
B = 2,3,5,7
F = DUAL ENTH Std type
GAS HEAT - BOTTOM OR REAR SUPPLY ONLY
f = FORW
ARD CURVE FAN Class II
C = 1,4,5,7
Y = 1,3,9,8
G = SINGLE ENTH Std type
g = AIR FOIL FAN [always Class II]
D = 2,4,5,7
Z = 2,3,9,8
H = DRY BULB Std type
HEAT SOURCE
2 = 2,4,9,8
N = NATURAL GAS
 Blower Mount
Q = 1,3,9,7
S = NATURAL GAS, SS HEAT EXCHANGER
h  =  Neoprene
R = 2,3,9,7
EXHAUST 
(See note 5)
D = NATURAL GAS, MODULATING  HEAT*
i  = 1  inch deflection spring
S = 1,4,9,7
A = BARO
J = 2, 5
S
 = A, 3 
T = NATURAL GAS, MODULATING  HEAT, SS *
j = 2 inch deflection spring
I = 1,3,5,8
T = 2,4,9,7
B = 1, 3
K
 = 2, 6
T
 = A, 4
  HEAT EXCHANGE
R
J = 2,3,5,8
7 = 1,4,9,8
C = 1, 4
L
 = 2, 7
U
 = A, 5
E = ELECTRIC HEAT
D = 1, 5
M
 = 2, 8
V
 = A, 6
C = COOLING ONLY 
 9 = Non-Std
E = 1, 6
N
 = NONE
W
 = A, 7
W
 = HOT W
A
TER COIL
ID MOTOR
 (See note 2)
F = 1, 7
O
 = 1, 9
X
 = A, 8
X = STEAM COIL
Condenser Coil
Head Press. Ctrl.
G = 1, 8
P
 = 1, 0
Y
 = A, 9
1 = STANDARD
7
 = YES
H = 2, 3
Q
 = 2, 9
Z
 = A, 0
2 = TECHNICOAT
8
 = NO
I =  2, 4
R
 = 2, 0
2
 = 8,000 CFM ERV
HEAT CAPACITY
Piping
 (
S
ee note 4)
3 = 13,000 CFM ERV
3 = 267 MBH
5 = 10 HI-EFF
3 = STANDARD  4 = HOT GAS BYPASS
5 = 533 MBH
6 = 15 HI-EFF
Evaporator Coil
9 = Non Std Config
8 = 800 MBH (40T ONLY)
7 = 20 HI-EFF
5 = STANDARD
Power Exhaust
4 = 40 KW
8 = 25 HI-EFF (Except 25T)
1 = MODULATING DAMPERS
A = VFD MODULATING
       MOTOR
8 = 80 KW
9 = STD W
/TECHNICOAT
2 = NON-MOD. (ON/OFF)
1 = 108 KW
 
(1)
0 = 7.5 HI-EFF (25T Only)
0 (ZERO) NO HEAT
Motor
1 = 1 ROW
0 = 5 HP HI-EFF (25T Only)
2 = 2 ROW
6 = 7.5 HP HI
-EFF
1 = 1 ROW
7 = 10 HP HI-EFF
8 = 15 HP HI-EFF (Except 25 Ton)
Config
A    
13
D     
14
3      
3
N      
5
A      
4
PACKAGE
3      
6
4      
7
FILTERS
C     
12
B      
8
1      
9
A     
10
A     
11
GENERATION
           
3  
        2
Z      
1
Z = York Brand R-410A
A = STAND.
B = 65%
C = 95%
D = 2" HI-EFF
A = 1,3,5,7
REFRIGERATION
(30T/40T)
3 = 30 TON
4 = 40 TON
2 = 25 TON
L = 2,4,5,8
BASIC UNIT
Class I blower is limited to 15HP in 25/30Ton
Class I blower is limited to 20HP in 40Ton
Class II blowers are not HP limited
K = 1,4,5,8
A = A, F, I
L
 = D, G, J
W
 = D, E, J
B = A, G, I
M
 = B, F, I
X
 = D, F, H
C = A, F, J
N
 = B, F, J
Y
 = B, E, H
D = A, G, J
O
 = B, G, I
Z
 = B, E, I
E = A, E, H
P
 = B, G, J
2
 = B, E, J
F = A, E, I
Q
 = C, F, I
3
 = B, F, H
G = A, E, J
R
 = C, F, J
4
 = C, E, H
H = A, F, H
S
 = C, G, I
6
 = C, E, I
I = D, F, I
T
 = C, G, J
7
 = C, E, J
J = D, F, J
U
 = D, E, H
8
 = C, F, H
9 = D, G, H
K = D, G, I
V
 = D, E, I
®
®
®