Belkin AP41300-12 User Manual

Page of 28
Hookup and Installation
Pur
eA
V P
o
w
er C
ons
ole
10
Step 3
Remote AC Operation
This function allows you to turn your Power Console on and off via your
preamplifier or receiver equipped with a switched AC power outlet. 
Note: You cannot turn off the switched outlets on the Power Console with
the switched button on the front of the unit when there is any
external power signal supplied to either the AC or DC remote inputs. 
To install the Remote AC Control Cable:
A. Plug the female end of the included Remote AC Control Cable into the
“Remote AC IN” outlet located on the back of the Power Console. (Fig. 3a)
B. Press the “Remote” button on the front of the Power Console to turn
on the remote function. The LCD display should read “REMOTE ON”.
(Fig. 3b)
C. Press the “Switched” button on the front of the Power Console to turn
off the switched outlets.
D. Connect the 2-pronged male end of the Remote AC Control Cable into 
a switched power outlet on a preamplifier or receiver. When you turn 
on the receiver or preamplifier, the outlets on the Power Console that
are programmed as “Switched” will be turned on immediately and the
“Switched/ Delayed” outlets will come on after a delay set by the
“Delay Time Switch”.
Figure 3a
Figure 3b