Enviro C-10078 User Manual

Page of 42
Flue Pipe Adaptor
Wall Framing
Wall Thimble
Fire Stop
Exhaust 4" Flex Pipe
Combusion Air 6 5/8" Flex Pipe
Wire Spacers
Horizontal Vent Termination
19
INSTALLATION INSTRUCTIONS:
1. Plan your installation and clearances to combustibles.  Decide on a location for the unit that will meet 
the clearances noted in the venting section, and any or all local code requirements. 
Wire
spacers
Figure 25: Wire Spacers.
2.  Set  the  appliance  in  the  desired  location.  Determine  if  any  wall  studs, 
electrical wiring, or plumbing pipes are in the way of the venting system as 
it passes through the exterior wall. The fireplace location should be adjusted 
if obstructions are found in the wall.
3. Project a line from the center point of the flue outlet upward and outward to 
the desired flue outlet location on the exterior wall. Using this center point, 
Initial Installation
QUALIFIED INSTALLERS ONLY
Figure 26: Wire Spacer in Place.
scribe a 10” (25.4 cm) hole or square on the 
wall. Cut the hole from the interior through 
the exterior wall surfaces.
4. Frame the hole as shown in Figure 29.
5.  Trim  the  wall  thimble  to  match  the  wall 
thickness  as  necessary.    Install  the  wall 
thimble  and  secure  it  to  the  inner  wall 
frame using four (4) 1½” wood screws.  If 
a wall is greater than 8” (203mm) in depth, 
the clearance above the flex must be 4⅜” 
(111mm)
Figure 27: Installation of Fireplace Horizontal Vent Kit.
6.  Apply  a  bead  of  Mill-Pac  Black 
sealant to the new Ø4” (10 cm) by 
5”  (12.5  cm)  provided  flue  collar 
adaptor.  Press the flue collar into 
the flue outlet of the fireplace so 
that  the  Mill-Pac  seals  the  flue 
collar to the flue outlet.  
7. Stretch both the Ø4” (10 cm) flex 
vent and the Ø6⅝” (16.25 cm) flex 
intake  liner  to  the  length  needed 
to  ensure  the  flex  can  be  easily 
connected to the vent terminal.
8.  Slide  the  Ø6⅝”  (16.25  cm)  flex 
intake  liner  over  the  flex  vent. 
Install  four  (4)  wire  spacers 
around  the  flex  pipe.  Ensure  the 
wire  spacers  are  positioned  at 
either  end  of  the  pipes,  and  at 
each  end  of  any  elbows  in  the 
liners (refer to Figure 25 and 26).