Sanyo 09KHS22 Leaflet

Page of 2
SUBMITTAL SHEET
SUBMITTAL SHEET
SUBMITTAL SHEET
SUBMITTAL SHEET
SYSTEM
INDOOR/OUTDOOR
09KHS22
09KHS22/CH0922
WALL MOUNTED  HEAT PUMP
             
   
          GENERAL DATA                (At   230V )
                                                             
  
POWER   V/PH/HZ
230 - 208/1/6
Circuit Ampacity, Min.  (A)
15
Fuse size, Max.             (A)
15
COMPRESSOR
Rotary-Hermetic
No. used
1
R.L. Amps - L.R. Amps (A)
4.0-30
Crankcase Heater
20W
OUTDOOR FAN - TYPE
Propeller
Dia. (in.) - No. used
15-3/4 - 1
Type Drive - No. speeds
Direct - 1
No. Poles - RPM 
6 - 820
No. Motors - HP   
1 - 1/38
CFM (High)
750
F.L. Amps. (A)
0.4
OUTDOOR COIL - TYPE
Aluminum Fin & Copper Pipe
Fin Type - Pipe Type
Slit Plate - Inner Riffled
Rows - F.P.I.
2 - 15.9
Face Area  (sq.ft.)
3.29
Tube Size  (in.)
3/8
INDOOR FAN - TYPE
Cross - Flow
Dia. & Length (in.) - No. used
3-17/32 & 24-5/8  - 1
No. speeds
3 & Auto
No. Poles -RPM  (High)
4-1,450
No. Motors - HP
1 - 1/75
CFM (HI/MED/LOW)
220/190/160
F.L. Amps (A)
0.2
INDOOR COIL - TYPE
Aluminum Fin & Copper Pipe
Fin Type - Pipe type
Slit Plate - Inner Riffled
Rows - F.P.I.
2 - 14.1
Face Area  (sq. ft.)
1.63
Tube Size  (in.)
3/8
Drain Connection Size (in.)
23/32
REFRIGERANT
R22
Lbs. - R22  (O.D. Unit)
2.91
Control
Capillary Tube
Connection
Flare
Line Length, Max   (ft.)
50
Lift difference, Max  (ft.)
23
Line Size - in. O.D. Discharge
1/4
Line Size - in. O.D. Suction
3/8
DIMENSIONS  (in.)
H
x
W
x
D
Indoor Unit
- Uncrated 13-19/32 x 31-  1/ 2
x 7- 3/32
- Crated
17-  3/16 x 33-  7/ 8
x 9 -21/32
Outdoor unit -Uncrated 20-  7/8
x 29-17/32 x 11-1/32
-Crated
23- 17/32 x 35-13/32 x 13- 7/8
WEIGHT
INDOOR OUTDOOR
Net
(lbs.)
24.3
 90.4
Shipping(lbs.)
28.7
97.0
Shipping Volume
(cu.ft.)
3.2
 
6.7
  
             
SS09KHS22-1
PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230/208V)
COOLING
Total Capacity
(BTU/H)
9,000/8,800
Sensible Capacity (BTU/H)
5,690/5,530
Latent Capacity
(BTU/H)
3,310/3,270
SEER
10.0/10.0
Dehumidification (Pints/H)
2.2/2.1
Amps
(A)
4.5/4.6
Power Inputs (W)
950/930
HEATING
Total Capacity
(BTU/H)
10,900/10,700
HSPF
6.8/6.8
Amps
(A)
4.7/4.8
Power Inputs (W)
1,030/980
Back-up Strip Heater (KW)
1.0/0.82
Outdoor Sound Rating (bels)
7.0
FEATURE
Controls
Microprocessor
Remote Controller
LCD Wireless type
Temperature Control
IC Thermostat
Timer
ON/OFF, 24 hours
Night Setback
Built-In
Air Louver (Horizontal)
Manual
                  (Vertical)
Manual
Power Failure Automatic Restart
Built-In
Self Diagnosis
Built-In
Heating/Cooling Automatic Changeover Built-In
OPTION
Refrigerant Line Set
AP0905BH    (15 ft)
AP0907BH    (20 ft)
    
AP0910BH    (30 ft)
Low Ambient Control
N/A
Fresh Air Intake
N/A
Central Remote ON-OFF Control
Available
Airduct Extension
N/A
Indoor Frame Extension
N/A
Condensate Drain Pump
Available
Non-Removable Remo-con Bracket
Available
OPERATING RANGE
Cooling
Indoor Air
Outdoor Air
Intake Temp.
Intake Temp.
Maximum
95 F DB/71 F WB
115 F DB
Minimum
67 F DB/57 F WB
67 F DB
Heating Maximum
80 F DB/67 F WB 
75 F WB/65 F WB
Minimum
-  F DB/ -  F WB 
17 F WB/15 F WB 
CERTIFICATION
09KHS22
AIRCONDITIONING PRODUCTS