HP 320 G6 505683-421 User Manual

Product codes
505683-421
Page of 50
Altitude
Operating
3048 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions were
measured in accordance with ISO 7779 (ECMA 74) and declared in accordance
with ISO 9296 (ECMA 109).
Idle
 
LWAd
6.25 B
LpAm
51.4dBA
Operating
 
LWAd
6.25 B
LpAm
51.4 dBA
Emissions Classification
(EMC)
FCC Rating
Class A
Normative Standards
CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15;
ICES-003; CNS13438; GB9254; K22;K24; EN
61000-3-2; EN 61000-3-3; EN 60950-1; IEC
60950-1
NOTE: Product conformance to cited product specifications is based on
sample (type) testing, evaluation, or assessment. This product or family of
products is eligible to bear the appropriate compliance logos and statements.
Power Supply
Input voltage
specifications
Rated input voltage
100 VAC to 240 VAC
Input Specifications
Rated input line
90 VAC to 264VAC
Frequency range
47 to 63 Hz
Rated input power
@ 115V input, Rated input power = 486W (assume
output wattage=450W
@ 230V input, Rated input power = 479W (assume
output wattage=450W)
Rated input current
6 A, 3 A (110 V, 220 V)
Steady state power
420W (rated)
BTU Rating
1710 BTU/hr
 
Ambient temperature
range
Operating
50° to 118° F (10° to 48° C)
Non-operating
-40° to 158° F (-40° to 70° C)
Relative humidity
(non-condensing)
Operating
55% to 85%
Non-operating
5% to 95%
Dielectric voltage
withstand
Input to output
1800 VAC/minute
Input to ground
1800 VAC/minute
QuickSpecs
HP ProLiant DL320 Generation 6 (G6)
Technical Specifications
DA - 13344   Worldwide — Version 59 — March 5, 2013
Page  48