Intel E5440 AT80574KJ073N Data Sheet

Product codes
AT80574KJ073N
Page of 118
47
Mechanical Specifications
3.2
Processor Component Keepout Zones
The processor may contain components on the substrate that define component 
keepout zone requirements. Decoupling capacitors are typically mounted to either the 
topside or landside of the package substrate. See 
 for keepout zones.
3.3
Package Loading Specifications
 provides dynamic and static load specifications for the processor package. 
These mechanical load limits should not be exceeded during heatsink assembly, 
mechanical stress testing or standard drop and shipping conditions. The heatsink 
attach solutions must not include continuous stress onto the processor with the 
exception of a uniform load to maintain the heatsink-to-processor thermal interface. 
Also, any mechanical system or component testing should not exceed these limits. The 
processor package substrate should not be used as a mechanical reference or load-
bearing surface for thermal or mechanical solutions.
Notes:
1.
These specifications apply to uniform compressive loading in a direction perpendicular to the IHS top 
surface.
2.
This is the minimum and maximum static force that can be applied by the heatsink and retention solution 
to maintain the heatsink and processor interface.
3.
These specifications are based on limited testing for design characterization. Loading limits are for the 
LGA771 socket.
4.
Dynamic compressive load applies to all board thickness.
5.
Dynamic loading is defined as an 11 ms duration average load superimposed on the static load 
requirement.
6.
Test condition used a heatsink mass of 1 lbm with 50 g acceleration measured at heatsink mass. The 
dynamic portion of this specification in the product application can have flexibility in specific values, but the 
ultimate product of mass times acceleration should not exceed this dynamic load.
7.
Transient bend is defined as the transient board deflection during manufacturing such as board assembly 
and system integration. It is a relatively slow bending event compared to shock and vibration tests.
8.
For more information on the transient bend limits, please refer to the MAS document titled Manufacturing 
with Intel
®
 components using 771-land LGA package that interfaces with the motherboard via a LGA771 
socket.
9.
Refer to the Quad-Core Intel® Xeon® Processor 5400 Series Thermal/Mechanical Design Guidelines 
(TMDG)for information on heatsink clip load metrology.
Table 3-1.
Package Loading Specifications
Parameter
Board 
Thickness
Min
Max
Unit
Notes
Static Compressive 
Load
1.57 mm
0.062” 
80
18
311
70
N
lbf
1,2,3,9
2.16 mm
0.085”
111
25
311
70
N
lbf
2.54 mm
0.100”
133
30
311
70
N
lbf
Dynamic 
Compressive Load
NA
NA
311 N (max static 
compressive load) 
+ 222 N dynamic 
loading
70 lbf (max static 
compressive load) 
+ 50 lbf dynamic 
loading
N
lbf
1,3,4,5,6
Transient Bend Limits
1.57 mm
0.062” 
NA
750
me
1,3,7,8