Intel Xeon E5405 BX80574E5405 User Manual

Product codes
BX80574E5405
Page of 100
Quad-Core Intel® Xeon® Processor 5400 Series TMDG
11
Introduction
§
T
CONTROL
A processor unique value for use in fan speed control mechanisms. T
CONTROL
 is a 
temperature specification based on a temperature reading from the processor’s Digital 
Thermal Sensor. T
CONTROL
 can be described as a trigger point for fan speed control 
implementation.
 
T
CONTROL
 = -T
OFFSET
.
T
OFFSET
An offset value from the TCC activation temperature value programmed into each 
processor during manufacturing and can be obtained by reading the 
IA_32_TEMPERATURE_TARGET MSR. This is a static and a unique value. Refer to the 
RS - Wolfdale Processor Family BIOS Writers Guide (BWG) for further details.
TDP
Thermal Design Power: Thermal solution should be designed to dissipate this target 
power level. TDP is not the maximum power that the processor can dissipate.
Thermal Monitor
A feature on the processor that can keep the processor’s die temperature within factory 
specifications under normal operating conditions.
Thermal Profile
Line that defines case temperature specification of a processor at a given power level.
TIM
Thermal Interface Material: The thermally conductive compound between the heatsink 
and the processor case. This material fills the air gaps and voids, and enhances the 
transfer of the heat from the processor case to the heatsink.
T
LA
The measured ambient temperature locally surrounding the processor. The ambient 
temperature should be measured just upstream of a passive heatsink or at the fan inlet 
for an active heatsink. 
T
SA
The system ambient air temperature external to a system chassis. This temperature is 
usually measured at the chassis air inlets.
U
A unit of measure used to define server rack spacing height. 1U is equal to 1.75 in, 2U 
equals 3.50 in, etc.
Table 1-2.
Terms and Descriptions (Sheet 2 of 2)