Husqvarna 123HD60 User Manual

Page of 24
16 – 
English
MAINTENANCE
Cooling system
To keep the working temperature as low as possible the 
machine is equipped with a cooling system.
The cooling system consists of:
1
Fins on the flywheel.
2
Cooling fins on the cylinder.
3
Cylinder cover (directs cold air over the cylinder).
Clean the cooling system with a brush once a week, more 
often in demanding conditions. A dirty or blocked cooling 
system results in the machine overheating which causes 
damage to the piston and cylinder.
Spark plug
The spark plug condition is influenced by:
Incorrect carburetor adjustment.
An incorrect fuel mixture (too much or incorrect type of 
oil).
A dirty air filter.
These factors cause deposits on the spark plug electrodes, 
which may result in operating problems and starting 
difficulties.
If the machine is low on power, difficult to start or runs poorly 
at idle speed: always check the spark plug first before taking 
any further action. If the spark plug is dirty, clean it and check 
that the electrode gap is 0.7 mm (0,028"). The spark plug 
should be replaced after about a month in operation or earlier 
if necessary.
CAUTION!  Always use the recommended spark plug type! 
Use of the wrong spark plug can damage the piston/cylinder. 
Check that the spark plug is fitted with a suppressor.
Air filter
The air filter must be regularly cleaned to remove dust and dirt 
in order to avoid:
Carburettor malfunctions
Starting problems
Loss of engine power
Unnecessary wear to engine parts
Excessive fuel consumption.
Clean the filter every 25 hours, or more regularly if conditions 
are exceptionally dusty.
Cleaning the air filter
Remove the air filter cover and take out the filter. Wash it 
clean in warm, soapy water. Ensure that the filter is dry before 
refitting it. 
An air filter that has been in use for a long time cannot be 
cleaned completely. The filter must therefore be replaced with 
a new one at regular intervals. A damaged air filter must 
always be replaced.
If the machine is used in dusty conditions the air filter should 
be soaked in oil. See instructions under the heading Oiling the 
air filter.
Oiling the air filter
Always use HUSQVARNA filter oil, art. no. 531 00 92-48. The 
filter oil contains a solvent to make it spread evenly through 
the filter. You should therefore avoid skin contact.
Put the filter in a plastic bag and pour the filter oil over it. 
Knead the plastic bag to distribute the oil. Squeeze the 
excess oil out of the filter inside the plastic bag and pour off 
the excess before fitting the filter to the machine. Never use 
common engine oil. This would drain through the filter quite 
quickly and collect in the bottom.
1
2
3