Advantech 8G ports Industrial Managed Redundant Gigabit Ethernet Switch User Manual

Page of 149
 
EKI-7758F User Manual                                                 114 
 
Here you can set up every port’s bandwidth rate and frame limitation type. 
 
•  Ingress Limit Frame type: select the frame type that wants to filter. The frame 
    types have 4 options for selecting: All, Broadcast/Multicast/Flooded Unicast, 
    Broadcast/Multicast and Broadcast only. Broadcast/Multicast/Flooded Unicast, 
    Broadcast/Multicast and Bbroadcast only types are only for ingress frames. The 
    egress rate only supports All type. 
 
•  All the ports support port ingress and egress rate control. For example, assume port 
    1 is 10Mbps, users can set it’s effective egress rate is 1Mbps, ingress rate is 
    500Kbps. The switch performs the ingress rate by packet counter to meet the 
    specified rate. 
 
•  Ingress: Enter the port effective ingress rate (The default value is “8192”) 
•  Egress: Enter the port effective egress rate (The default value is “0”) 
•  And then, click ‘Apply’ to apply the settings. 
 
 
Figure C.38: Rate Limiting