Instructions to Installer
1.  Installer  must  leave  instruction  manual  with  owner  after 
installation.
2.  Installer  must  have  owner  fill  out  and  mail  warranty  card 
supplied with the fireplace.
3.  Installer  should  show  owner  how  to  start  and  operate  the 
fireplace.
This is a B-Vent gas appliance and must be installed with a listed 
B-Vent vent system. The information contained in this manual 
pertains to all models and gas control systems unless otherwise 
noted.
Warning: This unit is not for use with solid fuels.
Appliance Certification 
This  fireplace  is  design  certified  in  accordance  with American 
National Standard/CSA Standard ANSI Z.21-50/CSA 2.22 and by 
Underwriters Laboratories as a Vented Gas Appliance and shall be 
installed according to these instructions.
Consult  your  local  building  code  agency,  prior  to  installation, 
to  ensure  compliance  with  local  codes-including  permits  and 
inspections.
The fireplace, when installed, must be electrically grounded in 
accordance with local codes or, in absence of local codes, with 
the National Electric Code ANSI/NFPA 70 if an external electrical 
source is utilized.
These models may be installed in a bedroom or bed-sitting room 
in the U.S.A.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment 
or  accessories  and  repair  and  servicing  of  equipment  shall  be 
performed only by a qualified agency. The term “qualified agency” 
means any individual, firm, corporation or company which either in 
person or through a representative is engaged in and is responsible 
for  (a)  the  installation  or  replacement  of  gas  piping  or  (b)  the 
connection, installation, repair or servicing of equipment, who is 
experienced in such work, familiar with all precautions required 
and has complied with all the requirements of the authority having 
jurisdiction.
State  of  Massachusetts:  The  installation  must  be  made 
by  a  licensed  plumber  or  gas  fitter  in  the  Commonwealth 
of  Massachusetts.  The  state  of  Massachusetts  requires  that 
a  flexible  appliance  connector  cannot  exceed  three  feet  in 
length.
The installation must conform with local codes or, in the absence of 
local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 
54* Natural Gas and Propane Installation Code, or CSA B149.1 
in Canada.
 *Available from the American National Standards Institute, Inc. 11 
West 42nd St., New York, N.Y. 10036.
Warning: ANY CHANGE TO THIS FIREPLACE OR ITS 
CONTROLS CAN BE DANGEROUS.
Improper installation or use of the fireplace can cause serious 
injury or death from fire, burns, explosions, or carbon monoxide 
poisoning.
Any  alteration  of  the  original  design,  installed  other  than 
as shown in these instructions or use with a type of gas not 
shown on the rating plate is the responsibility of the person 
and company making the change.
Important
All  correspondence  should  refer  to  complete  Model  Number, 
Serial Number and type of gas.
High Altitude 
When installing this unit at an elevation above 2000 feet (in the 
United States) it may be necessary to decrease the input rating by 
changing the existing burner orifice to a smaller size. Generally, 
input should be reduced 4 percent for each 1000 feet above sea 
level. However, if the heating value of the gas has been reduced, 
this general rule may not apply. Check with local gas utility for 
proper orifice size identification.
Canadian High Altitude 
Altitude: 0-4500 feet (0-1370 m)
When  installing  this  unit  at  an  elevation  above  4500  feet  (in 
Canada), check with local authorities.
Consult your local gas utility for assistance in determining the 
proper orifice for location.
Preparation
This gas fireplace and its components are tested and safe when 
installed in accordance with this Installation Manual. Report to 
your dealer any parts damaged in shipment, specifically check 
glass condition. Do not install unit with damaged, incomplete, or 
substitute parts. Read all instructions before starting installation 
and follow these instructions carefully during installation to insure 
maximum benefit and safety. Failure to follow them will void your 
warranty and may present a fire hazard.
The warranty will be voided by, and the warrantor disclaims any 
responsibility for the following actions:
•  Installation  of  any  damaged  fireplace  or  vent  system 
component.
•  Modification of the fireplace or vent system.
•  Installation other than as instructed by Empire Comfort Systems, 
Inc.
•  Improper positioning of the logs, glass door, optional accessories 
or decorative rock.
•  Installation and/or use of any component part not manufactured 
or approved by manufacturer.
Glass Specifications
Optional  glass  door  kits  manufactured  with  tempered  glass 
may  be  installed  in  hazardous  locations  such  as  bathtub  
enclosures as defined by the Consumer Product Safety Commission 
(CPSC). The tempered glass has been tested and certified to the  
requirements  of  ANSI  Z97.1  and  CPSC  16  CFR  1202  
(Safety Glazing Certification Council SGCC# 1595 and 1597.  
Architectural  Testing,  Inc.  Reports  02-31919.01  and  
02-31917.01).
This statement is in compliance with CPSC 16 CFR Section 
1201.5  "Certification  and  labeling  requirements"  which  refers 
to  15  U.S.  Code  (USC)  2063  stating  "...Such  certificate  shall  
accompany the product or shall otherwise be furnished to any 
INTRODUCTION