7.  Either pinch the clasp to release or cut each of the four 
(4) mounting studs (one in each corner of the Log Driver 
Board) that attach the circuit board to the chassis of the 
firebox.
!
 NOTE: If mounting studs are cut, ensure they are 
replaced by those supplied with replacement board.
8.  Clear both ends of mounting studs if cut.
9.  Install replacement mounting studs (if necessary) by 
pushing them through the sheet metal from the outside of 
the firebox.
10. Properly orientate replacement Log Driver Board and 
push onto mounting studs until all four (4) snap closed.
10. Remove one wire terminal from original Log Driver Board 
and install onto replacement Log Driver Board, matching 
its original position.
11. Continue with remaining wire connections, moving one 
wire at a time, matching its original position.
 WARNING:  Improper re-connection of wiring may result 
in electric shock, fire, or injury to persons.  Ensure that 
connections to/from circuit board match those of the 
respective wiring diagram for the particular model and 
MOD level being serviced (pages 7-10).
12. Once all connections are made, follow steps 1 and 2 in 
reverse order to reassemble the firebox.
Figure 21
Log Driver 