Desa (V)KC42NE Series User Manual

Page of 40
www.desatech.com
116240-01D
6
•  Your fireplace is designed to be used in zero 
clearance installations. Wall or framing material 
can be placed directly against any exterior sur-
face on the back, sides or top of your fireplace, 
except where standoff spacers are integrally 
attached. If standoff spacers are attached to your 
fireplace, these spacers can be placed directly 
against wall or framing material. See framing 
details on page 7.
•  If you plan on installing a television or enter-
tainment center recessed above your fireplace, it 
is recommended that you maintain a minimum 
18" above top of louver opening.
•  When locating termination cap, it is important 
to observe the minimum clearances shown in 
Figure 7, page 8.
•  If recessing into a wall, you can avoid extra 
framing by positioning your fireplace against 
an already existing framing member.
•  Do not recess termination cap into a wall or 
siding.
•  You may paint the termination cap with 450ºF 
(232ºC) heat-resistant paint to coordinate with 
the exterior finish. 
•  There must not be  any obstruction such as 
bushes, garden sheds, fences, decks or util-
ity buildings within 24" from the front of the 
termination cap.
•  Do not locate termination cap where excessive 
snow or ice build up may occur. Be sure to 
clear vent termination area after snow falls to 
prevent accidental blockage of venting system. 
When using snow blowers, do not direct snow 
towards vent termination area.
PRE-INSTALLATION 
PREPARATION
Continued
CLEARANCES
Minimum clearances to combustibles for the fire-
place are as follows:
*Back and sides 
0"/mm
Perpendicular walls 
6" (152 mm)
Floor 
0"/mm
Ceiling to louver opening  42" (1067 mm)
Front 
36" (914 mm)
Top of Standoffs 
0"/mm
Vent 
(See venting 
 
instructions for specific 
 
venting clearances.)
Combustible material with a maximum thick-
ness of 5/8" may be flush with the top front of 
fireplace.
* For back and sides of fireplace, do not pack 
with  insulation  or  other  materials.  Zero  inch 
clearance to combustible materials are for fram-
ing purpose only.
NOTICE:  This  fireplace  is  in-
tended for use as supplemental 
heat.  Use  this  fireplace  along 
with your primary heating sys-
tem. Do not install this fireplace 
as  your  primary  heat  source. 
If  you  have  a  central  heating 
system, you may run system’s 
circulating  blower  while  using 
fireplace. This will help circulate 
the heat throughout the house. 
In the event of a power outage, 
you can use this fireplace as a 
heat source.