POSSIBLE CAUSE
1. Control knob not fully pressed in
2. Control knob not pressed in 
long enough
3. Safety interlock system has 
been triggered 
4. Equipment shutoff valve not 
fully open
5. Pilot flame not touching ther-
mocouple, which allows ther-
mocouple to cool, causing pilot 
flame to go out. This problem 
could be caused by one or both 
of the following:
  A) Low gas pressure
  B) Dirty or partially clogged 
       ODS/pilot 
6. Thermocouple  connection 
loose at control valve 
7. Thermocouple damaged
8. Control valve damaged
1. Inlet gas pressure is too low
2. Burner orifice(s) clogged
3. Mislocated crossover tube
4. Burner orifice(s) diameter is 
too small
5. Remote  selector  in  OFF 
position 
6. Wire disconnected from gas 
control 
1. Manifold pressure is too low
2. Burner orifice(s) clogged
3. Mislocated crossover tube
1. Burner orifice is clogged or 
damaged
2. Damaged burner
3. Gas regulator defective
REMEDY 
1. Press in control knob fully
2. After ODS/pilot lights, keep con-
trol knob pressed in 30 seconds
3. Wait one minute for safety in-
terlock system to reset. Repeat 
ignition operation
4. Fully open equipment shutoff 
valve
5. A)  Contact  local  natural  or 
propane/LP gas company
 
  B)  Clean  ODS/pilot  (see 
Cleaning  and  Maintenance
page 20) or replace ODS/pilot 
assembly 
6. Hand tighten until snug, then 
tighten 1/4 turn more
7. Replace pilot assembly
8. Replace control valve
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner(s) (see Cleaning 
and Maintenance, page 20) or 
replace burner orifice(s)
3. Contact qualified service person
4. Replace burner orifice(s)
5. Put  remote  selector  in  ON 
position
6. See Wiring Diagram, page 21
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner(s) (see Cleaning 
and Maintenance, page 20) or 
replace burner orifice(s)
3. Contact qualified service person
1. Clean  burner  (see  Cleaning 
and Maintenance, page 20) or 
replace burner orifice
2. Replace damaged burner
3. Replace gas regulator
OBSERVED PROBLEM
ODS/pilot lights but flame goes 
out  when  control  knob  is  re-
leased
One or both burners do not light 
after ODS/pilot is lit
Delayed ignition of burner
Burner  backfiring  during  com-
bustion
TROUBLESHOOTING
Continued