A.O. Smith BFC - 100 User Manual

Page of 96
Service program
66
Instruction manual BFC
12
is
12.4 Displaying the appliance history
The appliance history submenu is used to display the 
burning hours, the number of ignitions, the number of 
flame errors and the number of ignition errors.
Call up the menu for displaying the appliance history 
as follows:
: APPLIANCE HISTORY
The figure shows an example.
12.5 Display the selected appliance
Call up the menu for displaying the appliance selection 
as follows:
: SELECT APPLIANCE
The appliance number can be found on the rating 
plate. 
The appliance selection has been correctly preset 
in the factory.
12.6 Switching the pump on or off
If a program-controlled pump is 
installed
, it can be switched ON or OFF as follows:
: PUMP RELAY
The standard setting for the pump relay is OFF.
If the mode WEEK PROGRAM or EXTRA PERIOD is 
active, then the setting for mode WEEK PROGRAM or 
EXTRA PERIOD
 has priority over the ON/OFF 
selection for the pump relay in the service menu.
Example
One of the week program periods is currently active. 
During this period, the pump relay setting is OFF. If the 
pump relay is set ON in the service menu, the pump 
will nonetheless remain OFF. The pump will only 
switch ON once the week program period has ended.
12.7 Setting the service interval
To aid servicing, the electronic controller includes a 
service interval which is used to set the frequency of 
maintenance interval
 by the service and maintenance engineer, 
based on the number of burning hours.
The service interval is based on the number of burning 
hours. This can be set to 500, 1000 and 1500 hours. 
The standard setting for number of hours is 500. Once 
the preset number of hours is reached, a 
message
.  to this effect will 
appear. Adjust the service interval via:
: SERVICE INTERVAL
12.8 Setting the display contrast
Adjust the display contrast via:
: CONTRAST DISPLAY
The standard setting is 100%. The range is from 0 
through 100%.
The figure shows the related display.
12.9 Setting the display backlight time
Set the backlight time (the time that the display 
backlight remains lit after the last button is pressed) as 
follows:
: TIME BACKLIGHT
The standard value is 255 s. The range is 0 to 255 
seconds.
The figure shows the related display.
12.10 Setting the display scroll speed
Adjust the control speed via:
: SCROLLSPEED
The default is 10. The range is from 0 through 100. 
Setting the value too high or low will make scrolling 
difficult.
APPLIANCE HISTORY
 BURNINGHOURS 000410
^IGNITIONS
001000
ÈFLAME ERRORS 000021
 IGNIT ERROR
000013
SELECT APPLIANCE
 »5934
^ 8576
È 3379
6527
....
PUMP RELAY
 »ON
OFF
SERVICE INTERVAL
 » 500      
^ 1000 BURNING HOURS
È 1500        
CONTRAST DISPLAY
» 95 %
TIME BACKLIGHT
» 255 sec
SCROLLSPEED
» 10