SPP Call Signaling Parameter Definitions 
(cont’d)
 
Field Name 
Values 
Description 
Single Port Protocol (SPP) 
[continued]
 
 
Client Options
 
Client Option fields are active 
only in registrar/client mode 
and only for client voip units.  
Primary 
Registrar  
-- 
This is the preferred SPP registrar 
gateway for controlling the traffic 
of the current voip. 
Alternate 
Registrar 1 and 
-- 
A first and a second alternate SPP 
Registrar gateway can be 
specified for use by the current 
voip for situations where the 
Primary Registrar gateway is busy 
or otherwise unavailable.  
Registrar IP 
Address 
n.n.n.n 
This is the IP address of the 
registrar voip to which this client 
is assigned. (Default value = 
0.0.0.0; effectively, there is no 
useful default value.) 
Registrar 
Port 
10000 or 
other 
This is the port number of the 
registrar voip to which this 
client is assigned. (Default port 
number = 10000.) 
Polling 
Interval 
integer 
60 - 300 
The interval between the voip 
gateway’s successive attempts to 
connect to and be governed by a 
higher level SPP registrar gateway.  
The Primary Registrar is the 
highest level registrar gateway.  
Alternate Registrar 1 is second; 
Alternate Registrar 2 is the lowest 
order SPP registrar gateway. 
Registrar Options
 
Registrar Option fields are 
active only in registrar/client 
mode and only for registrar 
voip units. 
Keep Alive 
(in sec.) 
30 – 300 
(seconds) 
Time-out duration before a 
registrar will unregister a 
client that does not send its 
“I’m here” signal.  Client 
normally sends its “I’m here” 
signal every 20 seconds.  
Timeout default = 60 seconds.