The Custom Tone-Pair Settings fields are described in the table below.   
 
Custom Tone-Pair Settings Definitions 
Field Name 
Values 
Description 
Tone Pair 
dial tone, 
busy tone, 
ring tone,  
‘unobtainable’ 
tone,  
survivability 
tone, 
re-order tone 
Identifies the type of telephony 
signaling tone for which 
frequencies are being specified. 
TONE PAIR VALUES 
About Defaults
:  US telephony 
values are used as defaults on 
this screen.  However, since this 
dialog box is provided to allow 
custom tone-pair settings, 
default values are essentially 
irrelevant. 
Frequency 1 
frequency in 
Hertz 
Frequency of lower tone of pair. 
This outbound tone pair enters 
the MultiVOIP at the input port. 
Frequency 2 
frequency in 
Hertz 
Frequency of higher tone of pair. 
This outbound tone pair enters 
the MultiVOIP at the input port. 
Gain 1 
gain in dB 
+3dB to –31dB 
and  “mute” 
setting 
Amplification factor of  lower 
frequency of pair. This figure 
describes amplification that the 
MultiVOIP applies to outbound 
tones entering the MultiVOIP at 
the input port.  Default = -16dB 
Gain 2 
gain in dB 
+3dB to –31dB 
and  “mute” 
setting 
Amplification factor of  higher 
frequency of pair. This figure 
describes amplification that the 
MultiVOIP applies to outbound 
tones entering the MultiVOIP at 
the input port.  Default = -16dB