4. Configuration Options
4-64
  
September 
2002
9128-A2-GB20-80
Manually Configuring DLCI Records
The Auto-Configuration feature automatically configures DLCI Records and their 
PVC Connections. DLCI Records can also be created manually (see 
).
Main Menu
 
Configuration
 
[Network/Data Port/ISDN/Virtual Router Ports]
 
DLCI Records
Available paths to DLCI Records Options depend on the FrameSaver model:
„
Data Port is available only on CSU/DSUs
„
ISDN is available only when the FrameSaver unit has an ISDN DBM installed
„
Virtual Router Ports is available only on the FrameSaver SLV Router
Typically, DLCI Records only need to be configured when building Management 
PVCs between the NOC and the central site unit; the unit automatically configures 
non-management DLCI Records and PVC Connections.
Table 4-14. DLCI Record Options (1 of 4) 
DLCI Number 
Possible Settings: 16 – 1007
Default Setting: Initially blank; no default.
Specifies the number for the DLCI in the DLCI record. The parameter determines which 
DLCI record is used for transferring data on a particular frame relay interface. DLCI 
numbers range from 0 to 1023. However, the numbers 0 – 15 and 1008 – 1023 are 
reserved. Entry of an invalid number results in the error message 
Value Out of Range 
(16 – 1007)
. If the DLCI number is part of a connection, this field is read-only.
NOTES:
– If a DLCI number is not entered, the DLCI record is not created.
– The DLCI number entered must be unique for the interface.
– Changing settings for this configuration option causes the FrameSaver unit to abort 
any active frame relay tests.
16 – 1007 – Specifies the DLCI number (inclusive).