Paradyne CSU User Manual

Page of 470
4. Configuration Options
4-76
  
September 
2002
9128-A2-GB20-80
TS Management Link Access Level
Available Settings: Level-1, Level-2
, Level-3
Default Setting: Level-1
Specifies the highest access level allowed when accessing the unit via a Telnet or FTP 
session when the service provider is using the TS Access Management Link.
Display Conditions – This option only appears when:
„
Service Type on the Easy Install screen is set to Frame Relay.
„
TS Access Management Link is set to a PVC name.
NOTES:
– Telnet and FTP sessions on this link 
are not  affected by the access level set by the 
Session Access Level, Login Required, or FTP Login Required option settings (see 
). 
– Telnet and FTP sessions on this link 
are affected by the Telnet Session, Inactivity 
Timeout, Disconnect Time and FTP Session option settings.
Level-1 – Allows Telnet or FTP access by network service providers with the capability to 
view unit information, change configuration options, and run tests. This is the highest 
access level allowed. Use this setting when downloading files.
Level-2 – Allows Telnet or FTP access by network service providers with the capability to 
view unit information and run tests only; they cannot change configuration options.
Level-3 – Allows Telnet access by network service providers with the capability to view 
unit information only; they cannot change configuration options or run tests.
TS Management SNMP Validation
Possible Settings: Enable, Disable
Default Setting: Disable
Specifies whether validation of community strings and IP addresses is performed for this 
management link. 
Display Conditions – This option only appears when:
„
Service Type on the Easy Install screen is set to Frame Relay.
„
TS Access Management Link is set to a PVC name.
Enable – Validation of community strings and IP addresses is performed on SNMP traffic.
Disable – No validation of community strings and IP addresses is performed.
Table 4-17. Node IP Options (3 of 3)