4. Configuration Options
4-88
  
September 
2002
9128-A2-GB20-80
Configuring SNMP Traps and Trap Dial-Out
Select SNMP Traps from the Management and Communication menu to configure 
SNMP traps and dial-out when a trap is generated (see 
).
Main Menu
Configuration
Management and Communication
 SNMP 
Traps
, for trap 
format standards and special trap features, including RMON-specific traps, and 
the default settings that will generate RMON-specific SNMP traps.
Access Type
Possible Settings: Read, Read/Write
Default Setting: Read
Specifies the type of access allowed for an authorized NMS when IP address validation is 
performed.
Display Conditions – This option appears for each trap manager specified in the 
Number of Trap Managers configuration option.
Read – Allows read-only access (SNMP Get command) to the MIB objects. This includes 
all objects specified as either read-only or read/write in the MIB RFCs.
Read/Write – Allows read and write access (SNMP Get and Set commands) to the MIB 
objects. However, access for all read-only objects is specified as read-only.
Table 4-21. SNMP NMS Security Options (2 of 2) 
Table 4-22. SNMP Traps and Trap Dial-Out Options (1 of 6) 
SNMP Traps
Possible Settings: Enable, Disable
Default Setting: Disable
Determines whether the FrameSaver unit sends trap messages to the currently 
configured SNMP trap manager(s).
Enable – Sends trap messages.
Disable – Does not send trap messages.
Number of Trap Managers 
Possible Settings: 1 – 6
Default Setting: 1
Specifies the number of SNMP management systems that will receive SNMP trap 
messages from the FrameSaver unit. An NMS IP Address must be configured in the NMS 
n IP Address configuration option for each trap manager to receive trap messages.
1 – 6 – Specifies the number of trap managers (inclusive).