Paradyne CSU User Manual

Page of 470
4. Configuration Options
4-94
  
September 
2002
9128-A2-GB20-80
Configuring Ethernet Management
For the FrameSaver SLV 9126-II or 9128-II, select Ethernet Management from the 
Management and Communication menu, or Ethernet Management Options 
Screen from the Easy Install screen, to configure the Ethernet port (see 
).
Main Menu
Configuration
Management and Communication
Ethernet Management
Main Menu
Easy Install
Ethernet Management Options Screen
Table 4-23. Ethernet Management Options (1 of 2) 
Interface Status 
Possible Settings: Enable, Disable
Default Setting: Disable
Determines whether the Ethernet port is being used and can be configured.
Enable – The port is active. It can receive Version 2 or IEEE 802.3 MAC frames and 
transmit Version 2 MAC frames only. When the Ethernet port is enabled, the 
Would you 
like to set the Node's IP Destination to Ethernet?
 prompt is displayed. 
„
If you select Yes, the Default IP Destination (see 
) is 
automatically changed to Ethernet, so the Ethernet port’s Default Gateway Address 
is used for packets that do not have a route. This is required when the NMS is on a 
different subnet than the unit.
„
If you select No, the COM port or a PVC will be used for packets without a route.
Disable – The port is not active. When the port is disabled, the following will occur:
„
No alarms or traps configured for the port will be generated.
„
All port uses that refer to the Ethernet port, like the Default IP Destination and Initial 
Route Destination, will be reset to their default values (see 
IP Address 
Possible Settings: 001.000.000.000 – 223.255.255.255, Clear
Default Setting: Clear (000.000.000.000)
Specifies the IP address needed to access the Ethernet port.
001.000.000.000 – 223.255.255.255 – Shows the IP address for the port, which can be 
viewed or edited. 
Clear – Fills the IP address with zeros.
Subnet Mask 
Possible Settings: 000.000.000.000 – 255.255.255.255, Clear
Default Setting: 000.000.000.000 
Specifies the subnet mask associated with the IP address that is needed to access the 
Ethernet port.
000.000.000.000 – 255.255.255.255 – Set the Ethernet port’s subnet mask. The range for 
each byte is 000 to 255.
Clear – Fills the subnet mask associated with the IP address with zeros.