4. Configuration Options
9128-A2-GB20-80
September 2002
4-97
Parity 
Possible Settings: None, Even, Odd
Default Setting: None
Provides a method of checking the accuracy of binary numbers for the COM port. A parity 
bit is added to the data to make the “1” bits of each character add up to either an odd or 
even number. Each character of transmitted data is approved as error-free if the “1” bits 
add up to an odd or even number as specified by this configuration option.
None – Provides no parity.
Even – Makes the sum of all 1 bits and its corresponding parity bit always even.
Odd – Makes the sum of all 1 bits and its corresponding parity bit always odd.
Stop Bits 
Possible Settings: 1, 2
Default Setting: 1
Determines the number of stop bits used for the COM port.
– Provides one stop bit.
– Provides two stop bits.
Ignore Control Leads 
Possible Settings: Disable, DTR 
Default Setting: Disable
Specifies whether DTR is used.
Display Conditions – This option does not apply to the FrameSaver SLV Router.
Disable – Treats control leads as standard operation.
DTR – Ignores DTR. This may be necessary when connecting to some PAD devices.
Login Required
Possible Settings: Enable, Disable
Default Setting: Disable
Determines whether a user ID and password (referred to as the login) is required in order 
to log on to the asynchronous terminal connected to the COM port.
Display Conditions – This option only appears when Port Use is set to Terminal.
Enable – Requires a login to access the menu-driven user interface.
Disable – Does not requires a login. 
Table 4-24. Communication Port Options (2 of 5)