Creating a Login
A login is required if security is enabled.
 
Security is enabled by the configuration 
options Login Required for the communication port, modem port, and Telnet Login 
Required or FTP Login Required for a Telnet or FTP Session.
U
p to six login ID/password combinations can be created using ASCII text, and 
each login must have a specified access level. Logins must be unique and they are 
case-sensitive.
Procedure
 
To create a login record:
1. Select Administer Logins.
Main Menu
Control
Administer Logins
2. Select New, and set the following configuration options, as appropriate. 
NOTE:
, should you be locked out inadvertently.
3. Save your changes.
When Save is complete, the cursor is repositioned at the Login ID field, ready 
for another entry.
 for 
more information about security configuration options.
In the field . . . 
Enter the . . .
Login ID
ID of 1 to 10 characters.
Password
Password from 1 to 10 characters.
Re-enter password
Password again to verify that you entered the correct 
password into the device.
Access Level
Access level: 1, 2, or 3.
„
Level-1 – User can add, change, and display 
configuration options, save, and perform device 
testing.
„
Level-2 – User can monitor and perform 
diagnostics, display status and configuration option 
information. 
„
Level-3 – User can only monitor and display status 
and configuration screens.
CAUTION: Make sure at least one login is set up for 