Paradyne CSU User Manual

Page of 470
7. Operation and Maintenance
7-8
  
September 
2002
9128-A2-GB20-80
LED Descriptions
, identifies the alarms that cause the Alarm LED to 
light. See 
, for network, DSX-1, 
and PRI interface LED information, 
, for user data port interface LED information, and 
 for Ethernet interface LED information.        
Table 7-1.
General Status LEDs (1 of 2) 
Label
Indiction
Color
What It Means
OK
1
Power and 
Operational 
Status
Green
ON – FrameSaver unit has power and it is 
operational.
OFF – FrameSaver unit is in a power-on 
self-test, or there is a failure.
ALM Operational 
Alarm ( Fail)
Red
ON – FrameSaver unit has just been reset, or an 
error or fault has been detected. 
Error/fault/alarm conditions: 
„
Alarm Indication Signal (AIS)
„
CTS Down
„
DBM BRI Card Failure
„
DBM Download Failed
„
DLCI Down
„
DTR Down
„
Ethernet Link Down
„
Exceeded Error Rate (EER)
„
Internal Modem Failed
„
ISDN Network Failed
„
LMI Down
„
Loss of Signal (LOS)
„
Network Communication Link Down
„
Out of Frame ( OOF)
„
Power Supply/Fan Failure
„
Primary or Secondary Clock Failed
„
Self-Test Failed
„
SLV Latency Exceeded
„
SLV Timeout
„
Suboptimal Link Rate
„
Two Level-1 Users Accessing Device
„
Yellow Alarm Signal
1
When an ISDN BRI DBM is installed, if the OK LED comes on then goes off during 
power recycling, the ISDN BRI DBM may have failed.
2
On the Display LEDs & Control Leads screen for the Model 9128-II only, FR Mode 
is On or Off. When On (highlighted), the FrameSaver unit is in Frame Relay mode.