Paradyne CSU User Manual

Page of 470
7. Operation and Maintenance
7-16
  
September 
2002
9128-A2-GB20-80
Please Wait
Command takes longer 
than 5 seconds.
Wait until message clears.
Port Inactive
(FrameSaver SLV 
9128-II only)
The port is disabled, or it 
supports synchronous data 
when a DTE Loopback was 
started.
No action is needed.
Resetting Device, 
Please Wait ...
Yes (or y) was entered in 
the 
Reset COM Port usage 
field of the System Paused 
menu.
No action needed.
Save Cancelled
(FrameSaver SLV 
9128-II only)
Changes were made on the 
Easy Install screen, but 
when it came to saving the 
changes, the Esc key was 
pressed or No was entered 
in response to the 
Save 
Changes?
 prompt.
No action is needed.
Test Active
No higher priority System 
and Test Status messages 
exist, and a test is running.
„
Contact service provider if test 
initiated by the network.
„
Wait until the test ends and 
message clears.
„
Cancel all tests from the Test 
screen ( Path: main/test).
„
Stop the test from the same 
screen the test was started 
from.
User Interface Already 
in Use
Two Telnet sessions are 
already in use when an 
attempt to access the 
menu-driven user interface 
through the COM port is 
made.
IP addresses and logins of 
the users currently 
accessing the interface are 
also provided.
„
Wait and try again.
„
Contact one of the IP address 
user and request that they log 
off.
User Interface Idle
Previously active session is 
now closed/ended, and 
access via the COM port is 
now available.
Log on to the FrameSaver unit.
Session has been ended 
due to timeout.
No action needed.
Table 7-6.
Device Messages (5 of 6) 
Message
What It Indicates
What To Do