Paradyne CSU User Manual

Page of 470
7. Operation and Maintenance
7-22
  
September 
2002
9128-A2-GB20-80
ISDN Link Profile Disabled 
ISDN Link Name
An ISDN backup call could not be made because the 
ISDN link profile specified Link Name is disabled 
(
Main Menu
Configuration
ISDN
Link Profiles).
ISDN Link Profile Invalid, 
ISDN Link Name
No phone numbers have been specified in the ISDN 
link profile (specified by 
ISDN Link Name).
ISDN Network Failed (Active/ Idle)
An ISDN network failure was detected when:
„
Active – Backup call was in progress.
„
Idle – DBM was in Idle mode.
LatExceed
IP_ Address, 
COS
x,DLCInnnn
1
An IP SLV Latency Threshold has been exceeded for 
the specified COS of the path. 
IP_Address is the IP 
address of the path endpoint, COS
x is the Class of 
Service ID associated with the path, and 
nnnn is the 
DLCI which contains the path.
Link
 Down Administratively, frame 
relay link
2
The specified frame relay link has been disabled by 
the unit due to LMI Behavior conditions or LMI 
Protocol on another link is in a failed state.
Link Profile Disabled, 
ISDN Link Name
An ISDN backup call could not be made because the 
specified link profile was disabled.
LLB Active, 
[Interface]
A network Line Loopback (LLB) is active on the 
specified interface.
LMI Discovery in Progress, 
frame 
relay link
Local Management Interface protocol discovery is in 
progress to determine which protocol will be used on 
the specified frame relay link.
LMI Down, 
frame relay link
The Local Management Interface(s) has been 
declared down for the specified frame relay link.
„
For an individual ISDN link, the message appears 
when LMI has been declared down on the link.
„
For a multilink aggregate link, the message 
appears when LMI has been declared down on all 
constituent links of the frame relay multilink.
LOS at DSX-1
A Loss of Signal (LOS) condition is detected on the 
DSX-1 interface. Clears when the ratio of ones to 
zeros received is greater than or equal to 12.5%. 
Possible reasons include:
„
DSX-1 cable problem.
„
No signal being transmitted from the DTE.
Table 7-8.
Health and Status Messages (3 of 7) 
Message
What It Indicates
1
nnnn indicates a DLCI number of 16 through 1007.
2
frame relay link is one of the following: 
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-
n. The frame relay link associated with the user data port.
– 
ISDN Link Name on a non-network ISDN DBM interface.
3
Does not apply to a TS Management Link DLCI.