Paradyne CSU User Manual

Page of 470
7. Operation and Maintenance
9128-A2-GB20-80
September 2002
7-35
Status
Identifies whether the physical 
interfaces, LMIs, and DLCIs are all 
enabled and active for this PVC 
connection.
Active *
„
The PVC is currently active.
Inactive
„
The PVC is inactive because:
– Alarm conditions and network 
and SLV communication 
status indicate that data 
cannot be successfully 
passed.
– The unit has disabled the 
interface or frame relay link 
due to internal operating 
conventions.
– Activation of an alternate 
virtual circuit is not warranted; 
that is, no alarm condition on 
the primary destination link 
has been detected.
Disabled
„
The PVC cannot be activated and 
is essentially disabled as a result 
of how the unit was configured. 
Possible causes:
– The physical interface at one 
or both ends of the PVC is/are 
disabled.
– The frame relay link on one or 
both ends of the PVC is/are 
disabled.
Invalid
„
Some portion of the PVC 
connection is not fully configured.
* For the circuit to be active, both Source and Destination Statuses must be Active.
Table 7-12. PVC Connection Status (2 of 2) 
Field
Status
What It Indicates