Paradyne CSU User Manual

Page of 470
1. About the FrameSaver SLV
1-6
  
September 
2002
9128-A2-GB20-80
„
Auto-Configuration. Provides the following automatic configuration features:
— Time Slot Discovery – For automatic configuration of all network DS0 
assignments. 
— Frame Relay Discovery – For automatic discovery of network DLCIs and 
configuration of a user data port DLCI, the PVC connection, and a 
management PVC, which is multiplexed with user data DLCIs.
— LMI Protocol Discovery – For automatic configuration of the protocol being 
used by the network.
— DLCI Deletion – For automatic removal of configuration of unused DLCIs 
from the unit’s configuration and statistical databases.
— CIR Determination – For automatic recalculation of the committed rate 
measurement interval (Tc) and excess burst size (Be) when a DLCI’s CIR 
changes.
— Excess burst size (Be) and committed burst size (Bc) are recalculated 
when Committed Burst Size Bc (Bits) is set to CIR. The committed rate 
measurement interval (Tc) is recalculated when Committed Burst Size Bc 
(Bits) is set to Other.
„
Maximum Number of PVCs and Management PVCs Supported.
„
Multiplexed Management PVCs. Provides a method of multiplexing 
management data with customer data transparently over a single PVC 
(Permanent Virtual Circuit) when FrameSaver devices are at each end of the 
circuit. This feature also makes it possible to run nondisruptive PVC tests.
„
Extensive Testing Capability. Provides a variety of tests to identify and 
diagnose device and network problems, including nondisruptive PVC 
loopbacks and end-to-end connectivity. Tests can be commanded from the 
unit’s menu-driven user interface or the OpenLane system.
These tests include V.54 or FT1-ANSI data channel loopback support so the 
frame relay network service provider can perform a physical loopback from its 
own switch without having to contact the local service provider for loopback 
activation.
„
LMI Packet Capture. Provides a way of uploading data that has been 
captured in a trace file so the data can be uploaded and transferred to a 
Network Associates Sniffer for analysis, or viewed via the menu-driven user 
interface. When viewed from the menu-driven user interface, the twelve most 
recent LMI messages are displayed via the LMI Trace Log.
Feature
FrameSaver 
SLV 9126-II 
Router
FrameSaver 
SLV 9126 
CSU/DSU
FrameSaver 
SLV 9126-II 
CSU/DSU 
FrameSaver 
SLV 9128-II 
CSU/DSU
Through 
Connections 
(PVCs)
8
16
64
120
Dedicated 
Management 
PVCs 
2
2
2
2