Paradyne CSU User Manual

Page of 470
8. Troubleshooting
8-20
  
September 
2002
9128-A2-GB20-80
Starting and Stopping a Test
Use this procedure to start, monitor, or abort specific tests. To abort all active tests 
on all interfaces, see 
Start or stop an individual test using the same procedure.
Procedure
 
To start and stop a loopback or a send-pattern test:
1. Follow this menu selection sequence:
Main Menu
Test
2. Select an interface and test (e.g., Network, Data Port, or ISDN PVC Tests) and 
press Enter. 
The selected test screen appears. 
Start
 appears in the Command column. 
Inactive
 appears in the Status column.
3. Select the Port number and press Enter.
4. Select the DLCI number and press Enter if a PVC test has been selected.
The cursor is positioned at Start in the Command column of the first available 
test and is highlighted.
5. To start the test, highlight 
Start
 under Command for the test you want to run 
and press Enter. 
Stop
 now appears and is highlighted, and the status of the 
test changes to 
Active
.
The length of time that the test has been running is shown in the Result 
column.
6. To stop the test, press Enter to send the Stop command. 
Start
 reappears 
and the status of the test changes back to 
Inactive
When the status of a test is . . .
The only command available is . . . 
Inactive
Start
Active
Stop