Paradyne CSU User Manual

Page of 470
8. Troubleshooting
8-22
  
September 
2002
9128-A2-GB20-80
PVC Tests
PVC tests can be run on a requested DLCI for a selected interface. 
„
When PVC tests are on a multiplexed DLCI between FrameSaver devices, 
they are nondisruptive to data, so user data can continue to be sent during a 
test.
„
If the device at one end of the circuit is not a FrameSaver device, PVC tests 
are on a standard DLCI and are disruptive to data. Also, the Connectivity test 
would not appear.
Loopback, and send/monitor pattern tests are available for each interface on the 
selected DLCI. FrameSaver devices should be at each end of the circuit. If a PVC 
Loopback is started at one end of the circuit, the other end can send and monitor 
pattern tests.
The example below shows a PVC Test screen for a FrameSaver unit with ISDN 
backup capability, with the multiplexed DLCI 550 selected. If a standard DLCI was 
selected, (
Disruptive
), rather than (
Non-Disruptive
), would be displayed 
after Test. Also, the Connectivity test would not appear. 
PVC Tests Screen Example
If the unit does not have the ISDN DBM feature, or if the ISDN Link Profile’s Link 
Status is disabled, 
Test Call
 does not appear. An Outbound Phone Number 
must be configured for 
Test Call
 to appear.
NOTE:
Errors encountered during these tests may be caused by mismatched CIRs in 
the two FrameSaver units. If errors are detected, verify the CIR configuration 
and retest.
main/test/network_pvc                                                    9128-II
Device Name: Node A                                              5/26/2000 23:32
                                  NETWORK PVC TESTS
    DLCI Number: 550
   Test (Non-Disruptive)      Command     Status      Result              
    PVC Loopback:             Start     
Inactive    0:00:00
    Send Pattern:             Start     
Inactive    0:00:00
    Monitor Pattern:          Start     
Inactive    0:00:00
                                                      Sequence Errors   99999+
                                                      Data Errors       99999+
    Connectivity:             Start     
Inactive    RndTrip Time (ms)
99999
    Test Call:                Stop      
Active      Frame Relay Link Up
--------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu      MainMenu   Exit