8. Troubleshooting
8-24
  
September 
2002
9128-A2-GB20-80
Send Pattern
This test sends packets filled with a hexadecimal 55 test pattern and sequence 
number over the selected interface and DLCI to another FrameSaver device.
To send a pattern test on a link:
Main Menu
Test
[Network PVC Tests/Data Port PVC Tests/
ISDN Call/PVC Tests]
If the CIR is zero, the pattern will be sent at a rate of 1000 bps.
Monitor Pattern
This test monitors packets filled with a hexadecimal 55 test pattern and sequence 
number over the selected interface and DLCI to another FrameSaver device.
To monitor a pattern test on a link:
Main Menu
Test
[Network PVC Tests/Data Port PVC Tests/
ISDN Call/PVC Tests]
The current number of sequence and data errors are shown under the Result 
column when the
 
FrameSaver unit is in sync. An 
Out of Sync
 message appears 
when 5 frames out of 25 are missing or out of sequence.
These error counts are updated every second. If the maximum count is reached, 
99999+
 appears in these fields.
If the selected DLCI is 
configured as . . . 
Then . . . 
And the default 
Rate (Kbps) setting is . . . 
Standard
(Disruptive)
 appears 
after Test
100% of CIR
Multiplexed
(Non-Disruptive)
 
appears after Test
10% of CIR