Paradyne CSU User Manual

Page of 470
8. Troubleshooting
9128-A2-GB20-80
September 2002
8-31
Send Line Loopback
The remote Line Loopback (LLB) up and down codes are in-band codes that allow 
control of a remote device. The LLB Up code invokes a line loopback in the remote 
unit while the LLB Down code terminates the remote line loopback. Network 
loopbacks are defined in AT&T TR 62411.
A remote LLB cannot be started when one of the following tests is active:
„
Any Loopback on the same interface.
„
Send Pattern Test on this network interface or any synchronous data port (Port 
Use set to Synchronous) assigned to this interface.
„
Send V.54 or FT1 Loopback, or Data Channel Loopback on any synchronous 
data port (Port Use set to Synchronous) and assigned to this network 
interface.
„
Data Channel Loopback on the frame relay link on this network interface.
Procedure
 
To start and stop a Line Loopback:
1. Follow this menu selection sequence:
Main Menu
Test
Network Physical Tests
2. Select the 
Up
 code in the Send Line Loopback row to put a remote device in 
loopback.
3. To start the test, highlight 
Send
 under Command in the Send Line Loopback 
row and press Enter. The code is sent for up to 10 seconds, or until an 
acknowledgement is received from the remote end. The length of time that the 
test has been running is shown in the Results column.
4. To stop the test, send the 
Down
 code to take the remote device out of 
loopback.