Paradyne CSU User Manual

Page of 470
8. Troubleshooting
8-34
  
September 
2002
9128-A2-GB20-80
Send and Monitor Pattern Tests
The pattern tests enable a FrameSaver unit to either send or monitor a known bit 
pattern. These tests generate industry-standard bit patterns that can be used to 
determine whether information is being correctly transmitted across a circuit. 
The following test patterns are available:
A Send Pattern test cannot be started when the following tests are running:
„
Any Loopback on the same interface.
„
Send Pattern Test on any port assigned to this network interface.
„
Send V.54 or FT1 Loopback, or Data Channel Loopback on any synchronous 
data port (Port Use set to Synchronous) and assigned to this network 
interface.
Procedure
 
To send and monitor a Pattern Test:
1. Follow this menu selection sequence:
Main Menu
Test
[Network Physical Tests/DSX-1 Physical Tests]
2. Select the desired pattern in the Send or Monitor field. If sending/monitoring a 
user-defined pattern, enter the the desired 2-byte hexadecimal value in the 
field next to Send or Monitor. 
When sending a pattern, the  InjectERR function key appears. Use InjectERR 
if you want to inject a bit error in the transmitted bit pattern.
3. To send a pattern, highlight the 
Send
 command to send a pattern and press 
Enter. 
To monitor the test, highlight the 
Start
 command and press Enter.
The length of time that the test has been running is shown in the Result 
column. An error count is also displayed. When monitoring a pattern, the 
ResetMon function key appears. ResetMon resets the error count to zero.
4. To stop the test, press Enter to send the 
Stop
 command. 
Start
 reappears 
and the status of the test changes back to 
Inactive
.
— 
QRSS
—  
511
— 
All-zeros
— 
2047
— 
All-ones
— 
2E15-1 (2
15
-1)
— 
1-in-8
— 
2E20-1 (2
20
-1)
— 
3-in-24
— 
User-defined 2-byte test pattern (a0a0)
— 
63