IP Ping Test – Procedure 2
Procedure
 
To ping the NMS at the central site:
1. Verify that the central site NMS has the FrameSaver unit’s IP address in its 
routing table so it can communicate with the FrameSaver unit.
2. Verify that the central site NMS’s router has the FrameSaver unit’s IP address 
in its routing table so it can communicate with the FrameSaver unit.
3. Verify that the central site NMS has been configured as an SNMP Trap 
Manager if the router is to route data, so a route has been configured within 
the FrameSaver unit.
Main Menu
Configuration
Management and Communication
SNMP Traps
Or, for a local DLCI between the central site FrameSaver unit and its router, 
verify that a Default IP Destination route has been configured.
Main Menu
Configuration
Management and Communication
Node IP
Default IP Destination
Configure both SNMP Traps and a Default IP Destination when PVC 
Multiplexing is used, as when using the Auto-Configuration feature.
4. Select the IP Ping test.
Main Menu
Test
IP Ping
5. Enter the IP Address of the central site NMS, then select Start.
6. Verify the results of the IP Ping test.
— While the test is running, 
In Progress...
 appears in the Status field.
— When the test is finished, 
Alive 
should appear as the Status. If any 
other message is displayed, additional testing is required. 
Lamp Test
The
 
FrameSaver unit supports a Lamp Test to verify that all LEDs are lighting and 
functioning properly. All LEDs flash or blink on and off at the same time every 1/2 
second during execution of the test. When the test is stopped, the LEDs are 
restored to their normal condition. 
Main Menu
Test
Lamp Test
If the Test Timeout configuration option is enabled and a Test Duration is set, the 
Lamp Test stops when the test duration expires. Se
 for additional information.