10. Setting Up NetScout Manager Plus for FrameSaver Devices
9128-A2-GB20-80
September 2002
10-11
Adding SLV Alarms Manually
Once DLCIs have been discovered, SLV alarms should be defined and assigned 
to each DLCI. 
When configuring alarms manually, every alarm must be configured for each DLCI; 
that is, if there are eight alarms and 20 DLCIs, 160 trap configurations must be 
created (8 x 20). For this reason, it is recommended that the OpenLane defaults 
be used. Follow the procedure below to configure alarms manually. 
To load OpenLane default settings for alarms, see 
Procedure
 
1. From the NetScout Manager Plus main window, with the FrameRelay and 
Admin radio buttons still selected, click on the Config Manager icon to open 
the Configuration Manager main window.
2. Select the Custom radio button from the Properties File area (in the upper 
right of the window), then Property... (down the center of the screen).
The Custom Property Editor window opens (see the window in 
3. Select a DLCI from the Trap list, and select the Add... button (to the right of the 
list). The Add Trap window opens.