Paradyne CSU User Manual

Page of 470
10. Setting Up NetScout Manager Plus for FrameSaver Devices
10-14
  
September 
2002
9128-A2-GB20-80
Procedure
 
1. Open a terminal window and go to $NSHOME/usr.
2. Copy an example or interface-specific file to a new file that contains the user 
history table number. 
3. Open the new file using a text editor.
The variables in the file are listed with their OIDs (Object IDs). The frame relay 
interface number 101015001 must replace @IFN, and the DLCI number to be 
monitored must replace @DLCI.
Example: 
frCircuitSentFrames    
Change “
1.3.6.1.2.1.10.32.2.1.6.@IFN.@DLCI
” 
to “
1.3.6.1.2.1.10.32.2.1.6.101015001.301
The only valid interface number for a FrameSaver SLV 9126, 9126-II, 9126-II 
Router, or 9128-II is 101015001.
4. Edit the new file, as needed.
Refer to 
Creating .UDH Files
 and 
Using Custom History
 in the 
NetScout Manager 
Plus User Guide
 for additional information. 
, for OID 
information for an interface.