Installing the User-Defined History Files
Once the user-defined history files have been created, the files need to be 
installed. History files are installed from the command-line prompt in NetScout 
Manager Plus. Should the FrameSaver unit be reset, these files will need to be 
reinstalled. The command used to install a new user history table is located in 
$NSHOME/bin.
CAUTION:
Do not use user_history_table_1 or 2. UserHistory1 and UserHistory2 
are the default user history files used to keep SLV data for reports. 
Editing either of these files will destroy SLV reporting capability.
Procedure
 
1. Type dvuhist -f 
agentname user_history_ table_ number
 config 
number_of_buckets interval download_ file
.udh to load user-defined history 
files for the frame relay link. 
Example: 
 
dvuhist -f Dallas51 3 config 30 60 Dallas51k.udh
The interval must be entered in seconds.
2. Type dvuhist -f 
agentname DLCI_number
” 
user_history_ table_ number  
config
 number_of_buckets interval  download_file
.udh to load user-defined 
history files for a specific DLCI.
Example: 
 
dvuhist -f “Dallas51 301” 3 config 30 60 Dallas301.udh
The same user history table number can be used for both the link and DLCI. 
For these examples, user history table number 3 will appear as UserHistory3 
on the History List. 
 to verify that the 
user-defined history files have been loaded.