Paradyne CSU User Manual

Page of 470
B. SNMP MIBs and Traps, and RMON Alarm Defaults
9128-A2-GB20-80
September 2002
B-15
enterpriseSecondary-
ClockFail(4)
„
devLastTrapString 
(devHealthAndStatus.- 
mib)
Operating software has detected 
that the secondary clock source 
has failed.
String: 
‘Secondary clock failed.’
enterpriseSecondary-
ClockFailClear(104)
Operating software has detected 
that the secondary clock source is 
operational again.
String: 
‘Secondary clock restored.’
enterpriseSelfTest-
Fail(2)
„
devLastTrapString 
(devHealthAndStatus.- 
mib)
Unit has completed 
(re)initialization and a hardware 
failure was detected.
String: 
‘Self test failed: $
s.’ ($s is the 
contents of devSelfTestResult.)
enterpriseTest-
Start(5)
For physical interfaces and 
frame relay links:
„
ifIndex (RFC 1573)
„
.0.0  (placeholder)
„
devLastTrapString 
(devHealthAndStatus.- 
mib
For virtual circuits (DLCIs):
„
devFrExtDlciIfIndex 
(devFrExt.mib)
„
devFrExtDlciDlci 
(devFrExt.mib)
„
devLastTrapString 
(devHealthAndStatus.- 
mib
At least one test has been started 
on an interface or virtual circuit.
String: 
‘$testString test started on 
$ifString.’ (e.g., ‘DTE Loopback 
test started on Sync Data Port 
S01P1.’)
enterpriseTest-
Stop(105)
All tests have been halted on an 
interface or virtual circuit.
String: 
‘$testString test stopped on 
$ifString.’ (e.g., ‘Disruptive PVC 
Loopback test stopped on DLCI 
100 of Sync Data Port S01P1 
frame relay.’)
Table B-7.
enterprise-Specific Traps and Variable-Bindings (3 of 3) 
Trap
Variable-Bindings
Possible Cause