Paradyne CSU User Manual

Page of 470
4. Configuration Options
4-26
  
September 
2002
9128-A2-GB20-80
8. Select Save, then select PgDn or PgUp. The Class of Service Definitions page 
reappears. In the Code Points Assigned column next to your selected name 
there is now a Y for Yes.
9. If latency and availability should be measured for the selected name, change 
the N in the Measure Latency & Availability column to Y.
10. Select Save.
To configure these options, Service Type on the Easy Install screen must be set to 
Frame Relay.
Table 4-2.
Class of Service Definitions  
Class of Svc Name
Possible Settings: 
ASCII Text Entry
Default Setting: 
For IDs 2–7: blank 
For ID 1: Default
Specifies a name to identify a Class of Service definition.
ASCII Text Entry – Enter a unique name for the definition (maximum length 8 characters).
Measure Latency & Availability
Possible Settings: N, Y
Default Setting: 
For IDs 2–7: N 
For ID 1: Y
Determines whether latency and availability are measured for this Class of Service ID. 
Display Conditions – This option is set to N and is read-only until the class of service is 
defined and code points are assigned to it.
N – Latency and availability are not measured for this Class of Service ID.
Y – Latency and availability are measured for this Class of Service ID.
Code Points Assigned
Possible Settings: Y, N
Default Setting: 
For IDs 2–7: N 
For ID 1: Y
This read-only field shows whether a Code Point has been assigned to this Class of 
Service ID on the Code Point Definitions screen.
– No Code Point is assigned to this ID.
Y – At least one Code Point is assigned to this ID.