Paradyne CSU User Manual

Page of 470
4. Configuration Options
9128-A2-GB20-80
September 2002
4-35
Line Build Out (LBO)
Possible Settings: 0.0,  –7.5,  –15, –22.5
Default Setting: 0.0
Specifies the line build out for the signal transmitted to the network.
0.0, –7.5, –15,  –22.5 – Specifies line build out in dB.
Bit Stuffing 
Possible Settings: 62411, Disable
Default Setting: 62411
Determines the type of bit insertion to provide ones density requirements for data 
transmitted to the network.
Display Conditions – This option does not appear when Line Coding Format is set to 
B8ZS.
62411 – Inserts a one in the data after 15 consecutive zeros are received or the density of 
ones falls below 12.5%. This setting complies with AT&T TR 62411, but is not 
recommended for frame relay data because it inserts errors in the data traffic.
Disable – Disables bit stuffing. Ones density is not enforced on data sent to the network.
Transmit Timing
Possible Settings: System, Interface
Default Setting: System
Allows transmit timing to be selected from either the system master clock source or from 
the currently selected interface.
System – Transmit timing is derived from the current system clock source (see 
).
Interface – Transmit timing is derived from this interface.
NOTE:  When Interface is configured, the clock must be synchronized to the system 
clock source.
Network Initiated LLB
Possible Settings: Enable, Disable
Default Setting: Enable
Allows the initiation and termination of the line loopback (LLB) to be controlled by the 
receipt of LLB-Actuate and LLB-Release commands from the network. 
Enable – LLB is controlled by LLB-Actuate and LLB-Release commands. Receiving a 
LLB-Actuate command causes the FrameSaver unit to enter a line loopback (provided an 
LLB can be performed in the FrameSaver unit’s current state). Receiving an LLB-Release 
command terminates the LLB.
Disable – The FrameSaver unit ignores the LLB-Actuate and LLB-Release commands.
NOTE:  When disabled, the system is not in compliance with ANSI T1.403 or 
AT&T TR 62411.
Table 4-6.
Network Physical Interface Options (2 of 4)