Paradyne CSU User Manual

Page of 470
4. Configuration Options
4-38
  
September 
2002
9128-A2-GB20-80
Configuring a User Data Port (CSU/DSUs)
Select Physical from the Data Ports menu to display or change the physical 
characteristics of the data port connected to the DTE (see 
Main Menu
Configuration
Data Ports
Physical
Table 4-7.
Data Port Physical Interface Options (1 of 5) 
Port Status
Possible Settings: Enable, Disable
Default Setting: Enable
Determines whether the data port is being used and can be configured.
Enable – The port is active, and can be used to transmit and receive data.
Disable – The port is not active. When the port is disabled, the following will occur:
„
No alarms or traps configured for the port will be generated.
„
LED for the port will be held in an Off state.
No – The operation is cancelled. (Pressing either the Esc or Ctrl-a key also acts as a 
No.)
Yes – Port status is disabled.
Port Use 
Possible Settings: Frame Relay, Synchronous Data
Default Setting: 
Frame Relay when the port supports frame relay. 
Synchronous Data
 when the port only supports synchronous data.
Determines how the data port will be used.
Display Conditions – This option only appears for user data on Port-2. 
Frame Relay – The port is configured for frame relay traffic. Frame relay links, DLCis, and 
PVC connections can be configured on this port.
Synchronous Data – The port is configured for standard TDM data, and can be 
cross-connected to a time slot on a T1 interface.
„
No alarms or traps configured for the port will be generated.
„
The LED for the port will be held in an Off state.
„
Existing cross-connect assignments associated with the port are cleared.