16 – Options—TDIF-1 card
 TASCAM DM-24 Reference Manual
 121
High sampling frequency considerations
NOTE
When cascading, all units must either be in high sam-
pling frequency mode or all units must be in normal 
sampling frequency mode.
Because of the reduced number of aux sends, the cas-
cade screen changes when the high-frequency mode 
is selected, as shown here:
TDIF-1 card
The optional TDIF-1 card provides an additional 
eight channels of I/O (four in high sampling fre-
quency mode).
As with the built-in TDIF-1 connectors, data can be 
accepted using 16, 20 or 24 bit word lengths to match 
the connected device. The card takes its values for 
these input parameters from the settings made in the 
MULTI I/O
The output parameters cannot be changed (fixed at 
24-bit, with the emphasis status echoing that of the 
input).
ADAT card
The optional ADAT card provides an addition eight 
channels of digital audio I/O using a “lightpipe” 
TOSLINK fiber connection.
Any word sync connection from an ADAT connected 
via this card must be made through the on-board 
WORD SYNC connector, as the card is not fitted 
with a word sync input.
The clock can be set as in the same way as for the 
built-in ADAT connection (“CLOCK settings” on 
page 24
).
All other parameters (word length and sampling fre-
quency) are determined by the ADAT device, and 
may not be set on this screen.
NOTE
This card cannot be used in high sampling frequency 
mode. A message is displayed in the appropriate part of 
the screen if the card is fitted and high sampling fre-