Tascam DM-24 User Manual

Page of 146
6 – Hookup—Synchronization and control connections
 TASCAM DM-24 Reference Manual
 47
ADAT connections
Use two TOSLINK-type fiber cables to connect the 
ADAT device (
ADAT IN
 to OUT on the remote 
device) and 
ADAT OUT
 to IN on the remote device).
If the ADAT is to be controlled from the DM-24, a 
third-party device to convert MMC to ADAT sync 
commands will be necessary. Examples of such 
devices are the JL Cooper dataSYNC
2
, or the MOTU 
MTP AV. These convert the ABS code from the 
ADAT to MTC, allowing synchronization for auto-
mation purposes.
Digital inputs and outputs
The two sets of digital inputs and two sets of digital 
outputs each comprise an XLR-type connector and 
an RCA pin jack. Typically, the XLR-type connector 
will be used for AES/EBU digital audio, while the 
RCA is used for SPDIF.
These inputs can be assigned to any of the channel 
modules (1 through 32). They can therefore be used 
as returns from digital effects units, etc. as well as 
source inputs from CD players, DAT decks, etc.
The DM-24 incorporates a sampling frequency con-
verter, allowing input from sources with a sampling 
frequency different from that of the DM-24.
The DM-24 can output audio data from both the 
XLR and the RCA connectors of each digital output 
at the same time.
Each of these output pairs can be used as the stereo 
mastering outputs, as paired buss outputs, as paired 
aux sends, or as the feed to the control room monitor-
ing system. 
The sampling frequency of the digital audio from 
these outputs is always the system sampling fre-
quency of the DM-24.
Synchronization and control connections
RS-422
TO METER
MIDI
THRU/
MTC OUT    OUT     IN
TIME CODE IN
External timecode 
source
MIDI equipment
MIDI equipment
P2-compatible 
equipment (e.g. VTR)
MU-24
To clock slave
From clock master
OUT/THRU     IN
WORD SYNC
DM-24