Tascam DM-24 User Manual

Page of 146
8 – Dynamics processors—Dynamics diagram
66 
TASCAM DM-24 Reference Manual
Dynamics diagram
The following display provides a graphical represen-
tation of the compressor settings, as shown below. As 
the signal is fed through the compressor, bargraph 
meters are shown on the appropriate scale:
Gates/expanders
The following parameters affect the gate and 
expander, if these have been assigned to the selected 
channel.
Gate
Threshold 
(
THRESH
), controlled by the POD 1 
knob, allows the setting of the threshold at which the 
gate will open. Variable from 
-80dB
 to 
0dB
 in 1dB 
steps.
Range 
(
RANGE
), controlled by the POD 2 knob, sets 
the gate range, from 
60dB
 to 
0dB
 in 1dB steps.
Hysteresis 
(
HYST
), controlled by the POD 3 knob, 
from 
0dB
 to 
24dB
 in 1dB steps.
Gate attack time 
(
ATTACK
), controlled by the 
POD 1 knob on the last row. Variable from 
0ms
 to 
125ms
 in 1ms steps.
Gate hold time 
(
HOLD
), controlled by the POD 2 
knob on the last row. Variable from 
0ms
 to 
990ms
 in 
100 steps.
Gate decay time 
(
DECAY
), controlled by the POD 
3 knob on the last row. Variable from 
50ms
 to 
5.0s
.
From 5ms to 200 ms, the steps are 5ms apart; from 
200ms to 300ms, the steps are 10ms apart; from 
300ms to 500ms, the steps are 20ms apart; from 
500ms to 1.00 s, the steps are 50 ms apart; from 1.00s 
to 3.00s, the steps are 0.1s apart; and from 3.00 s to 
5.00s the steps are 0.2s apart.
Expander
Threshold 
The threshold of the expander function, 
from 
–48dB
 to 
0dB
, in 1dB steps.
Ratio 
The ratio of the original signal relative to the 
expanded signal. Values are 1:1, 1:2, 1:4, 1:8, 1:16, 
1:32, 1:64.
Attack 
The attack time of the expansion effect. 
From 
0ms
 to 
125ms
 in 1ms steps.
Release 
The release time of the expansion effect. 
From 5ms to 5.00  seconds.
From 5ms to 200 ms, the steps are 5ms apart; from 
200ms to 300ms, the steps are 10ms apart; from 
300ms to 500ms, the steps are 20ms apart; from 
500ms to 1.00 s, the steps are 50 ms apart; from 1.00s 
to 3.00s, the steps are 0.1s apart; and from 3.00 s to 
5.00s the steps are 0.2s apart.
Output 
levels
Gain 
reduction
Compressor 
“knee”
Input levels