Tascam DM-24 User Manual

Page of 146
11 – Machine Control/Location—Selecting devices for control
 TASCAM DM-24 Reference Manual
 81
When an entry in the Machine Control List is high-
lighted (that is, the cursor is on the left of the screen), 
the dial is used to scroll through the list, including 
those items which may not be visible on the screen.
Deleting devices from the list
If a device is added in error to the Machine Control 
List (or is no longer required), highlight the device, 
move the cursor to the on-screen 
DELETE
 button, and 
press 
ENTER
. The last item in the list will be deleted.
This process can be repeated to clear the list.
Auto-detection of devices
In addition to the manual addition of controlled 
devices, there are two auto-detect buttons. One is 
used is used for detecting all devices attached to the 
DM-24 (
LIST AUTO DETECT
) and the other is used for 
Move the cursor to the on-screen 
LIST AUTO DETECT
 
button and press 
ENTER
 to scan the control ports and 
report on the detected devices, adding the controllers 
to the Machine Control list (see “Machine Control 
mapping memories” on page 82.
NOTE
Because not every device that may be controlled by the 
DM-24 is capable of reporting its presence accurately, 
some devices will not appear on the list, and must be 
added to the list manually. 
When attempting to identify a MIDI device, the DM-
24 first sends out an MMC Read Signature com-
mand. It adds a generic “closed loop” device for 
every device ID that responds to this command. 
It also sends out a MIDI Device Inquiry Message. If 
a remote device replies to this message, and an 
appropriate controller is available, this controller 
replaces the generic MMC closed-loop controller.
After power has been applied, it may take between 
one and two minutes for the remote devices to be rec-
ognized. Even if they have been added to the memo-
rized Machine Control list previously, it may not be 
possible to control them immediately the system is 
powered up.
Selecting the control type for the devices
The Machine Control list is composed of a number of 
columns. These are explained below:
STATE 
An icon shows the state of the controlled 
device. A one-way arrow represents an open-loop 
device (that is, commands are sent from the DM-24 
to the device, but no information is transmitted back 
from the device to the DM-24 along the same chan-
nel—information is transmitted from the other device 
through a different channel, such as timecode or 
MIDI). 
A double-ended arrow represents a closed loop, 
where information flows both ways between the 
remote device and the DM-24 along the same 
channel.
A cross indicates that the device is not being con-
trolled by the DM-24.
Two dashes (
--
) show that the type of control is not 
relevant here (for instance, the internal MIDI time-
code generator).
DEVICE 
The name of the name of the device being 
controlled, together with its control type. These list 
items cannot be changed or edited.
ID 
In the case of DTRS units, it refers to the unit ID, 
and cannot be edited. In the case of MMC units, it 
refers to the MMC ID (2 hexadecimal digits) of the 
unit. This list item cannot be changed or edited. Use 
the 
JOG
 dial to change the value and confirm with 
ENTER
.
CHASE 
This applies to DTRS units, and allows the 
CHASE mode of the selected unit to be turned on or 
off. Any unit which can have its chase mode con-
trolled by the DM-24 has this item represented by a 
square box. Units whose CHASE mode cannot be 
remotely controlled have this item represented by 
two dashes (
--
). Use the cursor keys to navigate to the 
list item, and the 
ENTER
 key to toggle between on (a 
check mark is shown in the box) and off (the box is 
empty).