       RS-232C Control Specification                                                      Page: 20 / 49 
Document Version [1.0]
 
Company Restricted 
 
 
 5-28. 
CLOCK (PICTURE ADJUST) Gain Data   
Function 
The external control equipment changes the CLOCK gain data (ratio of frequency division) of the plasma monitor. 
 
Transmission Data 
    DFH    80H    60H    7FH    03H    DATA00    DATA01    DATA02    CKS 
 
DATA00: USER PICTURE Gain Flag     
03H 
 
DATA01: CLOCK Gain Flag   
 
04H 
 
DATA02: CLOCK Gain   
 
C0H: -64 
  
 
 
  
FFH: 
-01 
  
00H: 
  
01H: 
+01 
  
 
  
40H: 
+64 
ACK 
  7FH  60H  80H  7FH  02H  DATA00  DATA01  CKS 
 
DATA00: USER PICTURE Gain Flag     
03H 
 
DATA01: CLOCK Gain Flag   
   
 
  04H 
 
 5-29. 
OSM ADJ. POSITION Data   
Function 
The external control equipment sets the position of the OSM menu of the plasma monitor. 
 
Transmission Data 
  DFH  80H  60H  1AH  02H  DATA00  DATA01  CKS 
 
DATA00: OSM ADJ. Gain Flag  
   
02H 
 DATA01 
 
  
 
 
   
01H: 
1(TOP 
LEFT) 
 
  
 
    
 
 02H: 
2(TOP 
CENTER) 
 
 
 
 
 
 
 
 
 
 
03H: 3(TOP RIGHT) 
 
  
 
    
 
 04H: 
4(BOTTOM 
LEFT) 
 
  
 
    
 
 05H: 
5(BOTTOM 
CENTER) 
 
   
 
 
06H: 6(BOTTOM RIGHT) 
ACK 
  7FH  60H  80H  1AH  01H  DATA00  CKS 
 
DATA00: OSM ADJ. Gain Flag   
   
02H 
 
 5-30. 
POWER MGT Select   
Function 
The external control equipment switches on or off the POWER MANAGEMENT of the plasma monitor. 
 
Transmission Data 
  DFH  80H  60H  1AH  02H  DATA00  DATA01  CKS 
 
DATA00: POWER MGT Select 
 
 
03H 
 DATA01 
 
  
 
 
   
01H: 
ON 
 
 
 
 
 
 
 
 
 
 
02H: OFF 
ACK 
  7FH  60H  80H  1AH  02H  DATA00  DATA01  CKS 
 
DATA00: POWER MGT Select 
 
 
03H 
 DATA01 
 
  
 
 
   
01H: 
ON 
 
 
 
 
 
 
 
 
 
 
02H: OFF