 5-46. 
MODEL NAME Request 
Function 
The external control equipment inquires the product code of the plasma monitor. 
 
Transmission Data 
  1FH  80H  60H  17H  00H  CKS 
ACK 
The plasma monitor returns the following ACK: 
  7FH  60H  80H  17H  0CH  DATA00 to DATA11  CKS 
 
DATA00: 1st character of the product code 
 
DATA01: 2nd character of the product code 
   
 
DATA11: 12th character of the product code 
 
     Received data  
  00H-09H  : 0-9 
                   
 
 
80H 
: - (Hyphen) 
81H : 
82H : 
 
83H : 
84H : 
85H : 
86H : 
87H : 
 
                   
 
 
96H            :    Blank 
 
                   
 
10H-29H 
: A-Z 
 
 
 
 
 
 
 
 
    If there are fewer than 12 characters in the product code, product code would be padded right with blanks. 
 
Example: If the product code of your plasma monitor is “PX-50XR5A”, the returned codes would be as follows. 
DATA00:1FH, DATA01:27H, DATA02:80H, DATA03:05H, DATA04:00H, DATA05:27H, DATA06:21H, DATA07:05H, 
DATA08:10H, DATA09:96H, DATA10:96H, DATA11:96H 
 
 
Corresponding 
character 
A B C D E F G H I  J 
Received 
data 
(H) 10 11 12 13 14 15 16 17 18 19 
Corresponding 
character 
K  L  M N O P  Q R S  T 
Received 
data 
(H) 1A 1B 1C 1D 1E 1F 20 21 22  23 
Corresponding 
character 
U V W X Y Z        
Received 
data 
(H) 24 25 26 27 28 29