Marantz PD4201 User Manual

Page of 49
PDxx01  
    RS-232C Control Specification 
Page: 36 / 49
Document Version [1.0]
 
 
Company Restricted 
 
 5-51. 
OSM ORBITER 
Function 
In order to decrease printing of a screen by OSM display, whenever it displays OSM, shift operation of the OSM is carried out. 
 
Transmission Data 
  DFH  80H  60H  5FH  01H  DATA00  CKS 
 
DATA00   
01H: ORBITER ON 
 
 
02H: ORBITER OFF 
ACK 
  7FH  60H  80H  5FH  01H  DATA00  CKS 
 
DATA00   
01H: ORBITER ON 
 
 
02H: ORBITER OFF 
 
 5-52. 
Input Skip 
Function 
In a monitor's key "an input change", when there is no signal, it flies and shifts to the following channel. 
 
Transmission Data 
  DFH  80H  60H  61H  01H  DATA00  CKS 
 DATA00 
  01H: 
ON 
  
02H: 
OFF 
ACK 
  7FH  60H  80H  61H  01H  DATA00  CKS 
 DATA00 
  01H: 
ON 
  
02H: 
OFF 
 
 5-53. 
SERIAL No. Request 
Function 
External control apparatus read 
the serial number of the set recorded by EEPROM of a plasma display. 
 
 
Transmission Data 
  1FH  80H  60H  15H  00H  CKS
 
 
ACK 
  7FH  60H  80H  15H  0CH  DATA00 to DATA11  CKS 
 
 
Even DATA00-DATA11 is set up as follows.
 
         
Setting value     00H-09H
 
:  0 - 9 
                   
 
96H   
:    Blank 
 
10H-29H   :  A-Z of Alphabet